One page per part. Each record lists the numbers the part replaces, the features that confirm it, the parts it gets confused with, and the sources behind every line. 39 records so far.
Two-handle Delta stem in hand? Look in the valve body where it sat. A seat and spring there mean a stem that seals on a seat, such as RP1740 or RP25513, and Delta RP1740 vs RP25513 tells those two apart. With no seat or spring there, read the two-handle ceramic disc stem record for Delta, Glacier Bay and Luxtra, which also covers Delta's own RP47422 ceramic stem.
Three-handle tub and shower: the center handle turns the diverter. On a Pfister valve, Pfister 910-382 vs 910-374 tells the threaded diverter stem from the smooth hot and cold stem; on a short American Standard Colony valve the center stem is the American Standard 50772-0700 short Colony diverter stem. For Pfister lavatory, kitchen and Roman tub faucets, the removable 1/2 in. x 20 seat has its own record: Pfister 970-510 valve seat. Single-lever showers: a square plastic stem on an older Kohler Coralais valve points to the Kohler GP71969 and Sterling 05200 mixer cap, the 4-1/2" stem of a Mixet non-pressure balance valve is the Mixet MS-5AT stem, and a Moen 1225 that needs only new seals takes the Moen 92451 seal kit.
Compression seats are told apart by thread and height: the Sterling 369X seat is 1/2 in. x 24, the American Standard 57281-07 seat is 1/2 in. x 20 and 7/16 in. tall, and the Sayco 1/2 in. x 20 seat is 5/16 in. tall. The seat, washer and gaskets for a Pfister 910-382 diverter stem come in one repair kit for that stem. A deep casting Pfister 0X8 shower valve takes the Pfister 974-042 pressure balance cartridge, 4-1/8 in. overall, which Pfister has replaced with 974-5299.
American Standard Colony tub and shower stems share a 16-point broach and come in two patterns: the 50729-0700 short stem for the short pattern valve and the 72855-0700 long stem for the long pattern valve. Old-style Kohler Trend faucets K-11606, K-11612, K-11616 and K-11620 take one stem on both the hot and cold side, Kohler 21076. The seat, washer, screw and packing for a Pfister 910-374 or 910-013 stem come as one Pfister 910-374 stem repair kit. Single-handle Ceramix and Reliant+ valves take the 47 mm American Standard 023529-0070A cartridge, and Kohler GP500520 vs GP876851 tells the Rite-Temp unit alone from the kit that adds a new mixer cap.
Look-alike comparisons
Parts that get mistaken for each other, side by side.